Details
The Aquacomputer Calitemp Temperature Sensor Inline and Outline G1/4 For Aquaero 5/6 is a digital coolant temperature sensor with one G1/4 inner thread and one G1/4 outer thread. It is connected to the aquabus of an aquaero 5 or aquaero 6 with firmware version 2100 or newer.
Properties
- Thread
- G1/4 internal and external, O-ring seal
- Connection
- aquabus, cable included
- Measuring range
- -30 °C to +120 °C, resolution 0.01 °C
- Material
- Nickel-plated brass body, silicone cover ring
How it fits
Aquacomputer rates this digital sensor for excellent accuracy over a wide temperature range. It has threads on both sides and can therefore be mounted directly on a CPU cooler or radiator to save space. Gently pulled from the metal part, the rubber ring with the cable connector turns into six positions.
What a run needs
For operation, an aquaero such as the aquaero 6 LT is additionally required. The supplied cable goes to its "aquabus high" connection, which supports a single Calitemp sensor without additional hardware; other aquabus devices share it through splitter 53124 or 53231. Alternatively, a maximum of four Calitemp sensors run on one aquaero via an "aquabus X4" (53258). Neither ships with it.
Compatibility
Compatible devices:
- aquaero 5 XT/PRO/LT, firmware version 2100 or newer, aquasuite 2018-1 or newer
- aquaero 6 XT/PRO/LT, firmware version 2100 or newer, aquasuite 2018-1 or newer
Aquacomputer notes that every aquasuite since version 2017 requires a valid license or activation; this sensor needs one for 2018 or newer, sold separately.
Specified absolute accuracy of the sensor chip used
| -40 °C to -20 °C | +/- 1 °C |
| -20 °C to -5 °C | +/- 0.5 °C |
| -5 °C to 50 °C | +/- 0.2 °C |
| 50 °C to 100 °C | +/- 0.5 °C |
| 100 °C to 125 °C | +/- 1 °C |
| Resolution | 0.01 °C |
Technical details
| Connection thread | G1/4 |
| Base body material | Nickel-plated brass |
| Cover material | Silicone |
| Height when installed | 16 mm |
| Temperature range | -30 °C to +120 °C |
| Supply voltage | 5 V DC |
| Supply current | max. 5 mA |
Notes
- Never connect multiple Calitemp sensors directly to an aquaero through splitters; use the aquabus X4.
- Real accuracy depends on the environment and is considerably lower in most cases; pipe insulation over the sensor improves it.
In the box
- 1x Calitemp set, which includes:
- 1x Calitemp sensor
- 1x aquabus connection cable (replacement part 53214)
The manual covers wiring and pin assignment.